Before testing, touch the test leads together. The meter should read zero or close to zero. If it reads a number, for example 5 ohms, then you will need to subtract 5 ohms from each reading.
Remove the Solenoid connector from the controller. Measure the resistance between pins 2 (Orange) and 3 (Black).
Resistance should be close to the value indicated in the chart for the approximate transmission temperature.
If you don't know the temperature of the transmission, let it sit long enough to equal ambient temperature.